The Frost protection function is automatically activated when the filtration management mode is in AUTO / THERMO-ADAPTIVE.
Frost protection mode operation is defined as follows:
If during the filtration times:
- Water temperature < 10°C: Filtration starts from 5 a.m. to 6 a.m. and from 10 p.m. to 11 p.m.
- T° < 3°C :
- Filtration runs for 15 minutes every 2 hours (if "Thermo-adaptive" mode activated from the platform)
- Filtration runs for 15 minutes every 8 hours (if "Thermo-adaptive" mode activated from the application)
- Water temperature < 1°C: filtration runs continuously.